LiftMaster 658202 Edge Pneumatic 2-Wire 14 ft. Air Hose

Special Order
What does this mean?
SKU
658202
Quick Overview

Pneumatic edge kit with exterior air switch. Includes 2-wire coil cord and 14 feet of air hose.

A sensing edge should be used on every door for the protection of pedestrians and vehicles. Depending on the type of edge and type of control wiring of the operator with which it is used, the function of the edge will vary.

Failsafe Edge:
A failsafe edge (or self monitoring edge) requires either a 3- or 4-wire connection and will not only cause a door to reverse while closing but will also render the door inoperable if the edge is not installed or if it becomes damaged after installation. A failsafe electric edge requires an operator with type F2 wiring or the use of a CPS IIoption board. The infrared link-edge is inherently failsafe and requires only type B2, C2, S2, T, T1 or TS control wiring.

$253.84

Secured and trusted checkout with

Pneumatic edge kit with exterior air switch. Includes 2-wire coil cord and 14 feet of air hose.

A sensing edge should be used on every door for the protection of pedestrians and vehicles. Depending on the type of edge and type of control wiring of the operator with which it is used, the function of the edge will vary.

Failsafe Edge:
A failsafe edge (or self monitoring edge) requires either a 3- or 4-wire connection and will not only cause a door to reverse while closing but will also render the door inoperable if the edge is not installed or if it becomes damaged after installation. A failsafe electric edge requires an operator with type F2 wiring or the use of a CPS IIoption board. The infrared link-edge is inherently failsafe and requires only type B2, C2, S2, T, T1 or TS control wiring.

Important Notes:

  1. SPECIFY LENGTH OF EDGE WHEN ORDERING. FOR ELECTRICAL EDGES, LENGTH EQUALS DAYLIGHT OPENING MINUS 2 INCHES. MINIMUM LENGTH - 5 FT.
  2. A COIL CORD OR TAKE-UP REEL IS REQUIRED WITH ALL EDGES. SOME FAILSAFE APPLICATIONS MAY REQUIRE A 3- OR 4-WIRE CORD. Consult your LiftMaster sales representative.
  3. TAKE-UP REELS ARE NOT RECOMMENDED FOR USE WITH ANY FAILSAFE TYPE EDGE. USE COIL CORDS ONLY.
  4. IF DOOR IS OVER 22 FEET WIDE, ELECTRIC EDGES OR PHOTO EYES ARE HIGHLY RECOMMENDED.

WARNING: It is strongly recommended that some type of safety equipment be used with every door operator. Without safety equipment, serious injury or death may result!